Sign In | Join Free | My burrillandco.com
Home > Oil Type Transformer >

6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers

    Buy cheap 6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers from wholesalers
     
    Buy cheap 6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers from wholesalers
    • Buy cheap 6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers from wholesalers
    • Buy cheap 6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers from wholesalers
    • Buy cheap 6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers from wholesalers
    • Buy cheap 6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers from wholesalers
    • Buy cheap 6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers from wholesalers

    6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers

    Ask Lasest Price
    Brand Name : WINLEY
    Model Number : S-6500/13.8
    Certification : CE,ISO
    Price : $1000-$150000
    Payment Terms : T/T
    Supply Ability : 500set/month
    Delivery Time : 30days
    • Product Details
    • Company Profile

    6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers

    6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers

    A Solar Double-Split Step-Up Transformer is a specialized transformer tailored for solar power systems. It uses dual split windings to efficiently raise the low-voltage output from solar panels (or an inverter) to a higher voltage suitable for grid connection or energy storage. The transformer splits the input across two separate windings and steps it up while preserving electrical isolation, thereby enhancing both efficiency and safety.

    Substation Transformer Main data
    SF-6500/13.8/0.48-0.48 specification data
    No.ParticularsUnitSpecification
    1Type~oil immersed, conservator type
    2Rated powerkVA6500
    3Power 1kVA3700KVA, Max. current 6000A
    4Power 2kVA2800KVA, Max. current 4500A
    5No. of Phase~3
    6Primary voltageV480Y/277-480Y/277
    7Primary connection 1~(4) 16-hole spade
    8Primary connection 2~(4) 12-hole spade
    9Secondary voltageV13800
    10Secondary connection~(3) 15kV Porcelain bushing
    11Tapping type~off circuit
    12Tapping range%±2*2.5%
    13Cooling method~ONAN
    14Rated frequencyHz60
    15Vector group~Dyn11,yn11
    16Insulation class~A
    17Ambiant temperaturefrom -10 to 40
    18Temperature riseK65
    Substation Power Transformer Drawing

    Features of Double-Split Transformers
    • Improved thermal distribution
      Splitting the core and winding into two symmetric halves evens out heat generation, reducing hot spots and improving cooling—important for reliable operation in high-temperature PV environments.
    • Better parallel operation
      Each half can run independently or together, enabling flexible load sharing and allowing the transformer to keep operating if one section is offline, increasing redundancy and availability.
    • Easier transport and installation
      Smaller, lighter components are easier to move to remote or mountainous sites, and on-site assembly is simpler—especially for prefabricated or skid-mounted stations.
    • Space-saving and modular
      The split design supports compact layouts (parallel or L-shaped), making it well suited for space-constrained, modular substations.
    • Lower electromagnetic interference (EMI)
      Balanced magnetic flux and current between the two halves reduce electromagnetic noise, aiding compliance with EMC requirements.
    • Maintenance flexibility
      One side can sometimes be taken offline for inspection or partial maintenance without stopping power delivery—valuable for critical sites like data centers or renewable hubs.
    Application

    Large photovoltaic power plants use 500 kW as the basic generation unit, and 500 kW inverters are the market standard. Connecting the inverter to the prefabricated (box-type) substation is a critical step in the PV system, so the design must balance cost control with technical soundness. The double-split transformer therefore offers an ideal voltage-boosting solution.

    PRODUCT SPECIFICATION
    Substation Transformer Specification
    kVAHVLVWidth(mm)Length(mm)Height(mm)
    315kVA11000V400V8006961336
    500kVA27600V480GrdY/277V173023001510
    500kVA11000V415V170017001650
    750kVA11000V433V185018451465
    1000kVA14400V415/240V108518601570
    1200kVA13800V240V245018501820
    1500kVA24940V600V180018801895
    2000kVA7200V600GrdY/346176626801982
    2000kVA44000V600V126020901700
    2500kVA24940V480GrdY/277V240022002060
    3000kVA11000V415V160023301920
    3000kVA22800V415/240V213035001910
    3750kVA44000V600V224026502700
    4000kVA33kV600Y/347215032502290
    5000kVA34500V7200V378018503450
    5000kVA34500V4160V279924002938
    6300kVA35000V400V352028203470
    6800kVA34500V800V340026703400
    7500kVA27600Y4160V335032902270

    More Substation transformers

    latest company news about Substation transformer 3 latest company news about Substation transformer 4 latest company news about Substation transformer 5

    Quality 6500 Kva Substation Power Transformer Step-Up 480V To 13800V Double-Split Solar Transformers for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xiamen Winley Electric Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)